A high-voltage transformer family for 110 kV and 115 kV networks with project-specific insulation, impedance, losses and cooling stages.

Temperature-rise duty: state the site ambient, altitude, load profile and MVA assigned to each cooling stage. See the thermal design and hot-spot guide.

Power-system duty: provide the system fault level, X/R basis, protection clearing time and operating cases with the RFQ. Review our transformer short-circuit withstand guide.

Oil-filled transformer project? Define the insulating liquid, sampling points, factory baseline and commissioning test package. See our DGA, moisture, BDV and sampling guide.

Replacement or parallel unit? Compare the existing unit with our transformer nameplate guide. If it will share a bus with another transformer, review the parallel-operation requirements before finalizing ratio, vector group, taps and impedance.

Product overview

110/115 kV Power Transformer is configured for utility transmission, large renewable plants and industrial grid connection. Apex coordinates technical review, qualified production, documentation and export delivery according to the approved project requirements.

Applications

utility transmission, large renewable plants and industrial grid connection. Final design considers the system study, load profile, fault level, installation environment, efficiency targets and local grid requirements.

Confirm the protection configuration

Specify the tank preservation arrangement and the required alarm, trip and remote indication functions. A conventional Buchholz relay requires a suitable conservator connection; PRD, OTI and WTI functions must be confirmed for the selected design. Contact types, auxiliary supplies and signal interfaces should be included in the approved scope.

Compare Buchholz, PRD and temperature-monitoring functions before finalising the accessory list. Drawings are helpful but optional for an initial enquiry.

Engineering and supply options

  • Project-specific voltage ratio, impedance and vector group
  • Loss evaluation and efficiency requirements
  • Protection, monitoring, metering and communication interfaces
  • Routine tests, agreed special tests and third-party inspection
  • Export packing, documentation and shipment coordination

Start your 110/115 kV transformer inquiry

For a utility or renewable project, share the grid connection voltage and the utility specification if available. Flag any required impedance, loss limits or cooling-stage ratings so quotations can be compared on the same basis.

Send a 110/115 kV transformer inquiry with your project location and what you know so far. A drawing or full specification is helpful, but not required to start.